AC CZPTal Single Section Enthusiast Motor for Air Cooler

HangCZPT Changpeng Motor Co., Ltd is a provider of motors for fan coil device, air conditioner, air cooler and other HVAC techniques , with experienced specialized gear, pursuit of quality and service, and integrity first. Our motors are nicely gained at property and abroad and can satisfy changing financial and social demands.

For the foreseeable future company relations and frequent good results, we sincerely welcome merchants from all walks of daily life to check out our manufacturing unit.

Functions:

· Made to fulfill manufacturer’s needs for travel ventilation units
· Capacitor Included And Mounted On PSC Designs
· Automated Reset Thermal Overload Protector
· Constant Responsibility,Air Over
· Ball CZPTs Unless of course Observed

CZPT Parameters

Design

(VOLTAGE) Frequency Output Electrical power Rated velocity ROT Cap(μF) Replaces
OEM product
YDK140-a hundred and twenty-6A 208-230 sixty 1/6HP 1075/2 SPD REVERSIBLE 5/370 PM31 0571
YDK140-one hundred twenty-6A5 208-230 60 1/6HP 1075RPM REVERSIBLE five/370 5KCP39DGS375S
YDK140-one hundred twenty-6A6 208-230 sixty one/6HP 1075RPM REVERSIBLE five/370 FSE1016SV1
YDK140-a hundred and twenty-6A7 a hundred and fifteen sixty one/6HP 1075/3 SPD REVERSIBLE five/370 5KCP39DGP729S
YDK140-a hundred and twenty-6A8 a hundred and fifteen sixty one/6HP 1075/three SPD REVERSIBLE 5/370 A.O.SMITH 9647
YDK140-one hundred fifty-6A 208-230 60 1/5HP 1075/two SPD REVERSIBLE five/370 PM310543
YDK140-one hundred fifty-6A2 220-240 fifty 1/5HP 900RPM CW-SE five/370 PM310544
YDK140-185-4A13 220/240 50 1/4HP 1050RPM REVERSIBLE 10/370 PM315711
YDK140-185-4A15 208-230 sixty 1/4HP 1625RPM REVERSIBLE 5/370 FASCO D783
YDK140-185-4A16 115 sixty one/4HP 1625RPM REVERSIBLE 5/370 FASCO D782
YDK140-185-6A10 208-230 sixty 1/4HP 1075RPM REVERSIBLE five/370 5KCP39FGM599T
YDK140-185-6A11 208-230 60 one/4HP 1075RPM REVERSIBLE 5/370 PM315710
YDK140-185-6A12 460 sixty one/4HP 1075RPM REVERSIBLE five/370 PM315719
YDK140-185-6A3 208-230 60 1/4HP 1075RPM REVERSIBLE 5/370 5KCP39EGP697T
YDK140-185-6A6 208-230 sixty one/4HP 1075RPM REVERSIBLE five/370 FASCO D725
YDK140-185-6A7 208-230 60 1/4HP 1075/3 SPD REVERSIBLE 7.five/370 FASCO D7909
YDK140-185-6A8 208-230 60 one/4HP 1075RPM REVERSIBLE five/370 FASCO D904
YDK140-185-6A9 a hundred and fifteen 60 one/4HP 1075RPM REVERSIBLE 5/370 A.O.SMITH a hundred thirty
YDK140-245-4A12 220 sixty one/3HP 1625/3 SPD REVERSIBLE five/370 PM310386
YDK140-245-4A13 208-230 60 1/3HP 1075RPM REVERSIBLE five/370 PM310385
YDK140-245-4A14 460 60 one/3HP 1075RPM REVERSIBLE five/370 PM310384
YDK140-245-4A17 208-230 60 one/3HP 1625/three SPD REVERSIBLE 5/370 FASCO D781
YDK140-245-4A18 208-230 60 1/3HP 1625RPM REVERSIBLE five/370 FASCO D787
YDK140-245-4A19 one hundred fifteen sixty 1/3HP 1625/3 SPD REVERSIBLE fifteen/370 FASCO D780
YDK140-245-6A10 208-230 sixty one/3HP 1075RPM REVERSIBLE seven.5/370 5KCP39MGG403ET
YDK140-245-6A2 208-230 sixty one/3HP 1075/three SPD REVERSIBLE seven.5/370 FASCO D923
YDK140-245-6A3 208-230 sixty 1/3HP 1075RPM REVERSIBLE seven.five/370 FASCO D7908
YDK140-245-6A4 208-230 60 1/3HP 1075RPM REVERSIBLE 7.5/370 5KCP39HGP698T
YDK140-245-6A9 208-230 sixty 1/3HP 1075/three SPD REVERSIBLE seven.five/370 A.O.SMITH 132
YDK140-370-6A2 a hundred and fifteen sixty one/2HP 1075 CE-LE 10/370 U26B1
YDK140-375-4A12 208-230 60 one/2HP 1625/3 SPD REVERSIBLE seven.5/370 FASCO D784
YDK140-375-4A13 208-230 sixty 1/2HP 1625RPM REVERSIBLE seven.5/370 FASCO D788
YDK140-375-4A14 one hundred fifteen sixty one/2HP 1625/3 SPD REVERSIBLE 15/370 FASCO D777
YDK140-375-4A9 208-230 sixty 1/2HP 1625/three SPD REVERSIBLE 5/370 PM3157186
YDK140-375-6A 208-230 60 1/2HP 1075RPM REVERSIBLE 10/370 5KCP39MGK209T
YDK140-375-6A10 208-230 sixty one/2HP 1075RPM REVERSIBLE 5/370 PM3

How to Examination Your AC Admirer Motor?

To examination the fan motor on your air conditioner, you may have to do a continuity examination. Simply click below for a video tutorial. Ahead of you begin, make positive the thermostat is set to awesome and that the temperature location is as low as it will go.

Phase 1. Verify the power

If you suspect the fan motor is negative, the initial thing you ought to check out is the electricity to the motor and the energy to the air conditioning unit. Identify the circuit breaker and make sure it hasn’t tripped. If the power is good, verify to see if there is correct voltage. You can do this at the transformer, examining for a fuse in the lower-voltage circuit.

Phase two. Examine the windings

Next, check the windings of the enthusiast motor for an open up or a brief. To do this, you are going to have to measure the ohms. If your fan motor is a 120V, it will most very likely have 4 coloured wires (black, blue, crimson, yellow, and many others.), as effectively as a white wire, a black wire, and two brown wires. If you might be doing work with the wires, do a resistance check in between the white wire and every of the coloured wires. The larger the resistance is, the reduce the speed is, with each coloured wire representing a various pace.

Search for a resistance studying. A looking through of zero signifies the supporter motor winding is most likely shorted and triggering the breaker to journey or blow. An infinite looking through, on the other hand, might point out an open up motor winding. If either of these conditions exists, the fan motor wants to be replaced.

Stage 3. Examine the capacitor

Hold in thoughts that just simply because the enthusiast motor isn’t running, isn’t going to mean it really is undesirable. If the electrical power offer is good and the windings are in very good shape, check the capacitor following.

The capacitor assists the fan motor operate. Delivering torque to the supporter motor, if the capacitor is defective, there will not be enough energy delivered and the blower wheel, fan belt, and other essential factors can cease to work.

To inspect the capacitor, make certain it is discharged. When it is discharged, use a capacitor tester to examine the microfarad reading. The looking through ought to be in ten percent of the rated capacitance on the capacitor. If the reading through does not match the score, change the capacitor.

Solution Attributes:

Use NSK

Little vibration

High effectiveness

Sensible construction

Nickel plating for shaft

Electrophoretic coating for enclosure

Lower sounds higher good quality rolling bearing

Lower temperature rise

About Us:

1.We are a professional motor manufacturer.

two.CZPTy yr 500,000 to 600,000pcs of electric powered motor ended up exported to other folks nations.

three.We check the materials prior to generation and a few to 4 instances when generating to make sure the products in excellent quality,

also we create in accordance to your quirement

4.Best production capability,best high quality control,very best services

five.We can be your OEM producer with your authorization of manufacturer.

 

AC Electrical Single Phase Fan Motor for Air Cooler