We offer a extensive assortment of thyristor module, diode module, SCR module, electricity module, quickly diode module, rapidly thyristor module. a bridge rectifier,single-stage bridge rectifier,3 stage bridge rectifier. 

 

Energy Module 

Function

Isolated mounting foundation

CZPT common package 

Foundation plate insulation utilizing AIN substrate   

CZPT appropriate packaging                          

Low CZPT voltage drop                                          

Large surge current Up to 5000V voltage CZPT on request

Push-pack construction, exceptional temperature attributes, and electricity cycling capacity

Underneath 350A modules are all forced air cooling,  above 400A modules, air-cooled and h2o-cooled optional

 

Application 

For motor drives, electricity offer, electricity transmission and distribution, railway transportation, steel smelting, 

machinery manufacturing, welding machines, chemical sector, renewable energy.

CE certificate

Datasheet

 

Variety IT(AV)   VDRM
VRRM
ITSM   IDRM
IRRM
di/dt dv/dt IGT VGT IH VTO rT Rth(j-c) Tj Fig
A V Ax103 mA A/μs V/μs mA v mA V ºC/ W ºC mm
MTx25 25 600-1800 .55  ten >50 >800 <50 <2 <50 .ninety 9.eighty .ninety five one hundred twenty five A
MTx40 40 one.00  ten >50 <150 <2 <150 .86 5.60 .68 A
MTx55 55 one.25  10 >50 <150 <2 <150 .87 3.70 .fifty four A
MTx70 70 one.60  15 >50 <150 <2 <150 .ninety 2.sixty five .42 A
MTx90 ninety 2.00 fifteen >100 <150 <2 <150 .90 2.84 .thirty A,B
MTx110 one hundred ten two.40  20 >100 <150 <2 <150 .eighty two.34 .26 A,B
MTx130 a hundred thirty 3.60 30 >100 <150 <3 <150 .90 two.12 .20 C
MTx160 160 5.40  30 >100 <150 <3 <150 .ninety one.fifty three .17 C
MTx200 two hundred seven.20  30 >100 <200 <3 <200 .85 1.34 .13 D
MTx250 250 8.50  thirty >100 <200 <3 <200 .85 .90 .12 D
MTx300 three hundred nine.30  40 >100 <200 <3 <200 .85 .75 .10 D
MTx350 350 11.0  40 >100 <200 <3 <200 .ninety .fifty .09 F
MTx400 400 12.0  fifty >100 <200 <3 <200 .eighty five .forty nine .09  F,N
MTx500 500 fourteen.5  50 >100 <200 <3 <200 .eighty five .forty .08  F,N
MTx600 600 seventeen.four fifty >100 <200 <3 <200 .86 .45 .075 H
MTx800 800 23.2 50 >100 <200 <3 <200 .nine .50 .065 J
 MTx1000
*
a thousand 28. 50 >100 <200 <3 <200 .87 .forty five .06 J
*MTx500 500 twelve. 50 >100 <200 <3 <200 .8 .sixty four .085 G
*MTx600
*
 
600 fifteen. fifty >100 <200 <3 <200 .eighty five .five .07 I
*MTx800 800 18. fifty >100 <200 <3 <200 .9 .4 .05 K
     
MTC                    MTA                  MTK                    MTX              MT

Note:  If VDRM/VRRM ≥2500V, Viso (AC)>3000V  otherwise =2500V, For module with VDRM/VRRM  from 2500 to 5000V remember to make contact with us         Tj=125ºC  Tc=eighty five ºC     * H2o cooling and Tc=55ºC

 

Kind IF(AV)   VRRM IFSM   IRRM VFO rF Rth(j-c) VISO Tj Fig
A V Ax10three mA V ºC/ W V ºC mm
MDx25 twenty five 600-1800 .65  10 .eighty ten.9 one.25 2500 a hundred and fifty A
MDx40 forty 1.00  ten .eighty 6.00 .ninety A
MDx55 fifty five 1.30  10 .eighty three.eighty .70 A
MDx70 70 one.80  fifteen .seventy six two.70 .fifty six A
MDx90 90 2.30 15 .seventy seven 2.twenty .45 A,B
MDx110 a hundred and ten two.60  20 .80 one.seventy five .35 A,B
MDx130 a hundred thirty 3.90 30 .eighty one.forty five .30 C
MDx160 one hundred sixty 6.00  thirty .79 one.35 .23 C
MDx200 200 8.00  30 .76 .90 .fourteen D
MDx250 250 11.0  30 .78 .88 .14 D
MDx300 300 twelve.5  forty .80 .65 .13 D
MDx350 350 fifteen.0  forty .80 .sixty one .10  F
MDx400 400 17.0  50 .seventy eight .50 .ten F,N
MDx500 500 19.
 
fifty .75 .32 .09 F,N
 MDx600 600 twenty.8 fifty .eighty two .40 .08 H
 MDx800 800 22. 50 .seventy eight .twenty five
five
.07 J
 MDx1000 1000 25. 50 .seventy five .forty five .065 J
*MDx500 five hundred thirteen. 50 .seventy eight .50
five
.ten G
*MDx600 600 15. 50 .75 .forty five .09 I
*MDx800 800 19. fifty .seventy five .34 .08 K
         
MDC                        MDA                     MDK                      MD

Be aware:  If VDRM/VRRM ≥2500V, Viso (AC)>3000V  otherwise =2500V, For module with VDRM/VRRM  from 2500 to 5000V you should speak to factory          Tc=100 ºC   * H2o cooling and Tc=85ºC
 

Sort IT(AV)   VDRM
VRRM
ITSM 
 IFSM 
IDRM
IRRM
di/dt dv/dt IGT VGT IH VTO rT Rth(j-c) Tj Fig
A V Ax10three mA A/μs V/μs mA v mA V ºC/ W ºC mm
MFx25 25 600-1800 .55  ten >50 >800 <50 <2 <50 .ninety 9.eighty .ninety five 125 A
MFx40 40 one.00  ten >50 <150 <2 <150 .86 5.60 .sixty eight A
MFx55 fifty five one.25  10 >50 <150 <2 <150 .87 three.70 .54 A
MFx70 70 one.60  fifteen >50 <150 <2 <150 .ninety two.sixty five .42 A
MFx90 ninety 2.00 fifteen >100 <150 <2 <150 .ninety two.eighty four .30 A,B
MFx110 110 2.40  20 >100 <150 <2 <150 .eighty two.34 .26 A,B
MFx130 a hundred thirty 3.60 thirty >100 <150 <3 <150 .90 2.12 .twenty C
MFx160 160 5.40  30 >100 <150 <3 <150 .90 one.53 .seventeen C
MFx200 two hundred seven.20  30 >100 <200 <3 <200 .eighty five 1.34 .13 D
MFx250 250 eight.50  thirty >100 <200 <3 <200 .85 .90 .twelve D
MFx300 300 9.30  forty >100 <200 <3 <200 .eighty five .seventy five .ten D
MFx350 350 11.0  40 >100 <200 <3 <200 .90 .fifty .09 F
MFx400 400 twelve.0  fifty >100 <200 <3 <200 .eighty five .forty nine .09  F,N
MFx500 500 14.5  fifty >100 <200 <3 <200 .eighty five .forty .08  F,N
MFx600 600 17.four 50 >100 <200 <3 <200 .86 .45 .075 H
MFx800 800 23.two fifty >100 <200 <3 <200 .nine .50 .065 J
MFx1000 one thousand 28. fifty >100 <200 <3 <200 .87 .45 .06 J
*MFx500 five hundred 12. 50 >100 <200 <3 <200 .8 .64 .085 G
*MFx600 600 fifteen. fifty >100 <200 <3 <200 .85 .5 .07 I
*MFx800 800 eighteen. fifty >100 <200 <3 <200 .nine .4 .05 K
                 
MFC                                MFA                                MFK                    

Be aware: If VDRM/VRRM ≥2500V, Viso (AC)>3000V  otherwise =2500V, For module with VDRM/VRRM  from 2500 to 5000V you should make contact with us         Tj=125ºC  Tc=85 ºC     * Water cooling and Tc=55ºC
MDS

Type IO   VRRM IFSM   IRRM VFO rF Rth(j-c) VISO Tj Fig
A V Ax103 mA V ºC/ W V ºC mm
MDS75 seventy five 600-1800 1.00  10 .eighty 4.70 .36 2500 150 L
MDS100 100 1.50  ten .80 four.33 .29 L
MDS160 160 2.60  ten .80 one.80 .eighteen M
MDS200 200 three.20  15 .eighty one.60 .fifteen M
MDS

 Note:Tc=a hundred ºC
MKC  MHC

IT(AV)   VDRM
VRRM
ITSM  IDRM
IRRM
di/dt dv/dt IGT VGT IH VTO rT Rth(j-c) Tq Tj Fig
A V Ax103 mA A/μs V/μs mA v mA V ºC/ W μs ºC mm
one hundred sixty 600-1600 four.30  thirty >200 >800 <150 <3 <150 .86 one.sixty six .fourteen 15-35 115 D
200 five.60  30 >200 <200 <3 <200 .ninety one.seventeen .10 15-35 F
three hundred 7.80  forty >200 <200 <3 <200 .88 .80 .07 15-35 H

 MZC

IT(AV)   VRRM IFSM  IRRM VFO RF Rth(j-c) Trr Tj Fig
A V Ax10three mA V ºC/ W μs ºC mm
one hundred sixty 600-1600 4.fifty 30 .eighty five one.forty .eighteen two. a hundred and forty D
two hundred 6.00 thirty .88 .ninety five .fourteen three. F
300 eight.30 forty .86 .60 .ten four. H

    

                       
         MKC                           MHC                         MZC

Be aware:  MKC MHC @ Tc=85ºC     MZC @Tc=100ºC   VISO (AC)>2500V

Define size:

Company Certification

Factory environment display:

 

Bridge Rectifier Railway Transportation Metal Smelting Module